07.97

7 Drive Machine Data (SIMODRIVE Drive MD)

7.3.2 Drive MD (data description)

Multiturn resolution absolute encoder motor

(as from SW 5)

1021

Default value

Lower input limit

Upper input limit

Units

4 096

0

65 535

rev/min

Active on

Power On

Number of revolutions of the motor that can be represented

Measuring increments of the absolute track motor

(as from SW 5)

1022

Default value

Lower input limit

Upper input limit

Units

8 192

512

8 388 607

Incr/rev

Active on

Power On

Number of measuring increments per mechanical revolution for serial transmission of the
absolute position value.

Servo loop motor absolute track (as from SW 5)

1023

Default value

Lower input limit

Upper input limit

Units

0000

0000

FFFF

Hex

Active on

Power On

Bit 0

Lighting failed

Replace encoder

Bit 1

Signal amplitude to small

Replace encoder

Bit 2

Code connection defective

Replace encoder

Bit 3

Overvoltage

Switch on/off, replace encoder

Bit 4

Undervoltage

Switch on/off, replace encoder

Bit 5

Overcurrent

Switch on/off, replace encoder

Bit 6

Battery change necessary

Change battery

Bit 7 +
Bit 13

= 0

CRC error on ENDAT interface

= 1

Check hardware, cable, encoder; replace, if
necessary

Bit 7 +
Bit 13

= 0

Check error

= 1

Check hardware, cable, encoder; replace, if
necessary

Bit 7 +
Bit 13

= 0

Error on correction of abs. track through

= 1

incremental track

Check hardware, cable, encoder; replace, if
necessary

Bit 8

Reserved

-

Bit 9

C/D track in encoder EQN 1325 defective

Switch on/off, replace encoder

Bit 10

Protocol cannot be cancelled

Switch on/off, replace encoder

Bit 11

SSI level detected on data line hardware

Check encoder type, replace

Bit 12

TIMEOUT on reading measured value

Repeat, replace hardware

Bit 13

See bit 7

Bit 14

Reserved

-

Bit 15

Encoder defective

Replace encoder

Note:

The system acknowledges an interchange of the encoder systems ERN 1387 (previous
incremental system) and EQN 1325 (absolute encoder system) during parameterization or
connection by aborting the measured value acquisition. The following incorrect combinations
are possible:

ERN 1387 present, EQN 1325 parameterized:
Abortion via recognition of missing EnDat interface on ERN 1387 (MD 1023, bit 11 or bit 12
set)

Only for FDD:
EQN 1325 present, ERN 1387 parameterized:
Abortion via recognition of missing C/D tracks for EQN 1325 (MD 1023, bit 9 set)

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

7–79

SINUMERIK 840C (IA)

Advertising