7 Drive Machine Data (SIMODRIVE Drive MD)

08.96

7.3.2 Drive MD (data description)

Band-stop filter natural frequency set speed filter 2

1521

Default value

Lower input limit

Upper input limit

Units

100

1

141

%

Active

at once

The description of this machine data is the same as that for machine data MD 1520!

Concealable alarms (Power On)

1600

Default value

Lower input limit

Upper input limit

Units

0000

0000

FFFF

Hex

Active

at once

This machine data allows power on 611D alarms to be concealed. The monitoring function is
activated if the appropriate bit = 0. All 611D monitoring functions are activated as standard.

Value table:

Bit 0

Internal error cannot be concealed

Bit 1

Space vector monitoring (as from SW 5 FDD/MSD)

Bit 2

Not assigned

Bit 3

Not assigned

Bit 4

Measuring circuit, motor measuring system

Bit 5

Absolute track monitoring

Bit 6

Not assigned

Bit 7

Not assigned

Bit 8

Zero mark monitoring, motor measuring system

Bit 9

Converter limit frequency too high

Bit 10

Medium frequency measurement, speed too high - not concealable

Bit 11

Medium frequency measured-value memory full - not concealable

Bits 12-14

Not assigned

Bit 15

Power section temperature monitor

7–134

©