7 Drive Machine Data (SIMODRIVE Drive MD)

04.96

7.2.2 FDD MD (data description - SW 3)

Graphic representation:

Adaptation of speed controller machine data by means of characteristic

n

MD 1411

K

P

, T

N

MD 1412

MD 1401

MD 1409

MD 1408

MD 1410

MD 1407

Lower speed

range with

constant P gain/

integral-action

time

Upper speed

range with

constant P gain/

integral-action

time

Adaptation
range

Upper adaptation speed

1412

Default value

Lower input limit

Upper input limit

Units

0

0

7 200

rev/min

Active

at once

Input of upper speed threshold for adaptation of the speed controller machine data. When the
adaptation function is active, the control machine data MD 1408 and MD 1410 are applied at
speeds n > MD 1412. In the medium range MD 1411 < n < MD 1412, linear interpolation
takes place between the two control machine data sets.

See machine data "Adaptation lower speed threshold" (MD 1411) for diagram.

Selection adaption speed controller

1413

Default value

Lower input limit

Upper input limit

Units

0

0

1

Active

at once

This machine data allows adaptation of the speed controller machine data to be controlled as a
function of speed.

Input 0:

The adaptation function is not active. The settings in control machine data
MD 1407 and MD 1409 are applicable over the entire speed range. Control
machine data MD 1408 and MD 1410 are not taken into account.

Input 1:

The adaptation function is active. See machine data MD 1411 and MD 1412 for
description.

7–66

©