7 Drive Machine Data (SIMODRIVE Drive MD)

08.96

7.3.2 Drive MD (data description)

Upper speed L

h

characteristic motor 1

1143

Default value

Lower input limit

Upper input limit

Units

0.0

0.0

50 000.0

rev/min

Active on

Power On

Input of upper speed limit for the L

h

characteristic (magnetizing inductivity L

h

) as specified on

the motor data sheet (non-Siemens motor) or automatic parameterization using machine data
"Motor code number" (MD 1102). In the field-weakening range, the magnetizing reactance X

n

increases linearly from the saturated value at the speed at which field weakening begins to the
unsaturated value at the upper limit speed of the L

h

characteristic (see diagram MD 1144).

Notes:

This machine data only applies to main spindle drives.

As from SW 5, this machine data is no longer used.

Gain factor L

h

-characteristic

1144

Default value

Lower input limit

Upper input limit

Units

0.0

100.0

500.0

%

Active on

Power On

Input of gain factor (L

h2

/L

h1

) of the L

h

characteristic (magnetizing reactance) as specified on

the motor data sheet (non-Siemens motor) or automatic parameterization using machine data
"Motor code number" (MD 1102). In the field-weakening range, the magnetizing inductivity L

h

increases linearly from the saturated value at the speed at which field weakening begins to the
unsaturated value at the upper limit speed of the L

h

characteristic.

Graphic representation:

n

MD 1142

Rated value L

h1

n

L

h2

L

h

100 %

MD 1142

MD 1143

MD 1144

Notes:

If the value is unknown, then 100 % should be entered in order to obtain constant
magnetizing reactance over the entire speed range.

This data is relevant only for MSD drives.

As from SW 5, this machine data is no longer used.