7 Drive Machine Data (SIMODRIVE Drive MD)

08.96

7.3.2 Drive MD (data description)

Upper speed L

h

characteristic motor 1

1143

Default value

Lower input limit

Upper input limit

Units

0.0

0.0

50 000.0

rev/min

Active on

Power On

Input of upper speed limit for the L

h

characteristic (magnetizing inductivity L

h

) as specified on

the motor data sheet (non-Siemens motor) or automatic parameterization using machine data
"Motor code number" (MD 1102). In the field-weakening range, the magnetizing reactance X

n

increases linearly from the saturated value at the speed at which field weakening begins to the
unsaturated value at the upper limit speed of the L

h

characteristic (see diagram MD 1144).

Notes:

•

This machine data only applies to main spindle drives.

•

As from SW 5, this machine data is no longer used.

Gain factor L

h

-characteristic

1144

Default value

Lower input limit

Upper input limit

Units

0.0

100.0

500.0

%

Active on

Power On

Input of gain factor (L

h2

/L

h1

) of the L

h

characteristic (magnetizing reactance) as specified on

the motor data sheet (non-Siemens motor) or automatic parameterization using machine data
"Motor code number" (MD 1102). In the field-weakening range, the magnetizing inductivity L

h

increases linearly from the saturated value at the speed at which field weakening begins to the
unsaturated value at the upper limit speed of the L

h

characteristic.

Graphic representation:

n

MD 1142

Rated value L

h1

n

L

h2

L

h

100 %

MD 1142

MD 1143

MD 1144

Notes:

•

If the value is unknown, then 100 % should be entered in order to obtain constant
magnetizing reactance over the entire speed range.

•

This data is relevant only for MSD drives.

•

As from SW 5, this machine data is no longer used.