6 NC Machine Data (NC MD), NC Setting Data (NC SD)

07.97

6.4 Axis-specific MD 1 (axial data 1)

Delay time zero speed monitoring

372*

Default value

Lower input limit

Upper input limit

Units

200

0

1 000

ms

Active on

Reset

NC MD 372* is used to specify the amount of time that is to elapse before zero speed
monitoring (NC MD 212*) is to be activated during the approach to position (set speed=0).
The time must be chosen so as to enable suppression of the largest possible following error.
Failure to specify an appropriate delay time will trigger alarm 112*.

If NC MD 372* is 0, the value defined in NC MD 156 ("Servo enable cutoff delay") is taken as
delay time for zero speed monitoring.

MD 372*

Time

S

S

MD 212*

Normal case :

S

<

MD 212*

MD 372*

Time

S

S

MD 212*

Error situation :

S

>

MD 212*

S....Following error (contouring error)

Acceleration during emergency retraction

guided by the control

376*

Default value

Lower input limit

Upper input limit

Units

0

0

99 000 000

10 000units/s

2

Active on

You can enter your own acceleration in this MD. An emergency retraction block an thus be
made to respond more quickly.
If the value=0, the acceleration is taken from machine data 276* or from the parameter set for
acceleration.