12 Functional Descriptions

08.96

12.33.3 Current setpoint filter

Amplitude response

Magnitude
[dB]

log f [Hz]

10

2

10

3

10

3
0

-3

-10

-20

-30

Phase
angle

log f [Hz]

10

2

10

3

180

90

0

-90

-180

2000 Hz

2000 Hz

1000 Hz

500 Hz

1000 Hz

500 Hz

Fig. 12-6

Frequency response of undamped bandstop with a bandwidth of 500 Hz and
blocking frequency variations of 500 Hz, 1000 Hz and 2000 Hz.

12–344

© Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)

Advertising