Siemens SINUMERIK 840C User Manual

Page 231

Advertising
background image

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

09.95

6.4 Axis-specific MD 1 (axial data 1)

K

v

factor

252*

Default value

Lower input limit

Upper input limit

Units

1 666

0

10 000

80 000 (as from SW 5)

0.01 s

-1

Active on
NC Stop

When specifying the K

V

factor, attention must be paid to the fact that the gain factor for the

entire position control loop is dependent on other controlled system parameters. Strictly
speaking, a distinction must therefore be made between the "required K

V

factor" (which is

specified in NC MD 252*) and the "actual K

V

factor" (obtained at the machine). Only when all

control loop parameters have been correctly attuned to one another are these two K

V

factors

identical. The parameters in question are:

Max. velocity (MD 280*)

Speed setpoint adaptation MD 256*, 260*

Tacho compensation on the speed controller

Tacho-generator on the drive

An input value of 1 666 is equivalent to a K

V

factor of 1.

The position controller loop is broken if the value 0 is entered.

Note:

Axes which are to interpolate and perform a machining operation together must exhibit
precisely the same gain in the position control loop (i.e. at the same speed they must exhibit
the same following error = 45 degree inclination).

Any deviations will result in contouring errors!

Only axes which never contribute to continuous-path operation may be defined with different
values.

The actual K

V

factor can be checked on the basis of the following error (in the Service

displays). Note that the drift must be compensated before carrying out the check.

Note:

As from SW 4, for 8 parameter sets

Scaling factor max. velocity

256*

Default value

Lower input limit

Upper input limit

Units

10 000

1

99 999 999

mm

inch degr.

–––– –––– ––––

min

min

min

Active for all

channels of

mode groups

in STOP

The maximum load velocity is calculated from the maximum motor speed, the mechanical gear
and/or the spindle pitch.

with

r

=

transmission [1]

n

max

=

max. motor speed [

V

/

min

]

s

=

spindle pitch [mm]

For linear axes:

max. load velocity = n

max

· s · r

For rotary axes:

max. load velocity = n

max

· r · 360 degrees

See Section Axis (Analog) and Spindle Installation.

Note:

As from SW 4, for 8 parameter sets

6–46

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)