6 NC Machine Data (NC MD), NC Setting Data (NC SD)

01.99

6.6.1 General MD bits (general bits)

Bit 2

Bit 2 = 0,

Auxiliary function output during axis movement

Bit 2 = 1,

Auxiliary function output prior to travel

Active:

NC Stop

If an auxiliary function (M, S, T, H, D) is also programmed in a traversing block,
bit 2 can bring about the following two states:

Example:

N10

N15 M6 X100 LF
N20

(t)

N20

N15

N10

(V)

Velocity

Bit 2 = 0

M6

N10

(V)

M6

(t)

Bit 2 = 1

PLC cycle

Bit 1=1

If the bit is set, the internal WAIT mark synchronization is active.

Bit 1=0

WAIT mark synchronization via PLC

Active: NC STOP

Note:

Observe the internal WAIT MARK SYNCHRONIZATION DB 10-15 DL 15.8 interface signal as
from SW 6.3

Bit 0=1

No NC STOP in dwell block G04 S.../G14/G24. NC STOP is not active in
these blocks, but only at the end of the block.

Bit 0=0

NC STOP is immediately active; the dwell time and thus the block are aborted
completely. The next block is started with NC START.

Active: NC STOP

Note
A dwell time with G04 x..., G04 F... is always aborted by NC STOP.