Siemens SINUMERIK 840C User Manual

Page 608

Advertising
background image

8 PLC Machine Data (PLC MD)

09.95

8.5 PLC MD for the operating system (system bits)

6030

DL 15

4

3

2

1

PLC MD

DB63

DW No.

Bit No.

7

6

5

4

3

2

1

0

Error/operational messages

on inactive channels

1)

Default value:

All bits default to 0

0 signal:

Corresponding inactive channel DB is not used to activate error/operational
messages.

1 signal:

The inactive channel DB is used to activate error/operational messages.

Example:

PLC MD 6000

0

0

0

0

0

0

1

1

Only the error bits in the active channel DBs (DB10, DB11) for channels 1 and 2 are
evaluated.

PLC MD 6030

0

0

0

0

1

1

0

0

The error bits in the inactive channel DBs (DB12, DB13) for channels 3 and 4 are also
evaluated.

Note:

If an error bit is set in an inactive channel DB that is used for the extended display of error and
operational messages, then the corresponding errors are not included in the message group
displays.

You are not permitted to assign PLC channels (MD 6000) while the display of error and
operational messages for unused channels (MD 6030) is active, as it would result in
corruption and falsification of the displays. Also refer to the PLC Installation Section.

Example:

MD 6000.0 = 1 and
MD 6030.0 = 1

_______

1)

No longer exists from SW 4 onwards, new alarm concept