Axis-specific MD 2 (axial data 2)

SW prelimit switch

1100*

Default value

Lower input limit

Upper input limit

Units

20 000

- 99 999 999

99 999 999

units (MS)

Active

at once

Defines the distance at which the braking operation is to be prematurely begun if the current
speed exceeds the speed in NC MD 1, thus ensuring that the position of the software limit
switch will be overrun only to a negligible degree during circular interpolation.

Overshooting of the pre-limit switch triggers alarm 3091 except in the case of rapid traverse.

Recommendation

The value entered should be slightly higher than the value which would correspond to the
braking distance from rapid traverse to NC MD 1.

In program mode, travel movements which would result in overshooting of the software limit
switch position are simply not started (alarm 2065 is triggered).

Exception!

Circular interpolation, helical interpolation

Start of deceleration to zero speed

Reduction to NC MD 1

A

E

Software limit
switch

Software pre-
limit switch

Machine data for the ”Setup mode division-related” function.

Number of divisions

1104*

Default value

Lower input limit

Upper input limit

Units

0

0

999

Active

at once

Input limits: The value 0 is allowed only if the axis involved is not an indexing axis

(NC MD 564* bit 4 = 0).

The number of divisions gives the divisions per division reference dimension (NC MD 1108*).