6 NC Machine Data (NC MD), NC Setting Data (NC SD)

6.7 Axis-specific MD 2 (axial data 2)

u: Impulses variable incremental weighting 2nd measuring

system

1)

1208*

Default value

Lower input limit

Upper input limit

Units

1

0

65000

1)

9999 9999

2)

Active on

Power On

Active:

After Power On

Applies to feed axes only.

See MD 364*, 368*.

v: Traversing path variable incremental weighting 2nd

measuring system

1)

1212*

Default value

Lower input limit

Upper input limit

Units

1

0

65 000

1)

9999 9999

2)

units (MS)

Active on

Power On

Active:

After POWER ON

Applies to feed axes only.

See MD 364*, 368*.

Switchover tolerance 1st/2nd measuring system

1216*

Default value

Lower input limit

Upper input limit

Units

0

1000

3)

0

16 000

units (MS)

Active on

Power On

Active:

After Power On

Applies only to feed axes (not to C axes for spindles).

This machine data defines the maximum tolerance between the actual value of the first
measuring system and the actual value of the second measuring system which must not be
exceeded at the time of switching from one measuring system to another. Otherwise a setpoint
value jump occurs because the position controller tries to compensate for the change in the
actual value. To prevent this it is not possible to switch from one measuring system to another
when the tolerance is not maintained and the alarm 1016* ”Measuring system switchover not
possible” is output.

Servo gain (Kv) factor 3rd parameter set

1220*

Default value

Lower input limit

Upper input limit

Units

1 666

0

10 000

80 000 (as from SW 5)

0.01s

-1

Active on

Power On

This MD has the same meaning as MD 252*, see also functional description of parameter set
switchover.