Siemens SINUMERIK 840C User Manual

Page 560

Advertising
background image

07.97

7 Drive Machine Data (SIMODRIVE Drive MD)

7.3.2 Drive MD (data description)

Voltage step for generator control

1632

Default value

Lower input limit

Upper input limit

Units

30

0

300

V

Active

at once

Input of response threshold of DC link voltage. In conjunction with machine data "Response
voltage generator axis" (MD 1631), this data defines the voltage range for the upper threshold
of the two-step controller for generator operation.

Note:

This machine data is described under the additional function "Extended shutdown and
retraction (G420...G426)", see Programming Guide 840C.

Cutout threshold generative mode

1633

Default value

Lower input limit

Upper input limit

Units

510

0

580

660 (as from SW 6)

V

Active

at once

Input of cutout threshold of DC link voltage. If the voltage exceeds this threshold value, the
motor switches from generator mode back to normal operation.

Note:

This machine data is described under the additional function "Extended shutdown and
retraction (G420...G426)", see Programming Guide 840C.

Response threshold emergency retraction

1634

Default value

Lower input limit

Upper input limit

Units

400

0

580

660 (as from SW 6)

V

Active

at once

Input of response threshold of DC link voltage; if the voltage drops below this value,
emergency retraction responses are initiated according to the operating modes selected in
machine data "Drive modes emergency retraction" (MD 1636).

Note:

This machine data is described under the additional function "Extended shutdown and
retraction (G420...G426)", see Programming Guide 840C.

Minimum speed generator axis

1635

Default value

Lower input limit

Upper input limit

Units

0.0

0.0

50 000.0

1/min

Active

at once

Input of minimum DC link generator speed. Bit 3 in the ZK2 register is set if the speed drops
below the value set here. This message is output to inform the NC that the drive operaing in
generator mode (MD 1636) has reached a speed at which the NC should initiate an
emergency retraction.

Note:

This machine data is described under the additional function "Extended shutdown and
retraction (G420...G426)", see Programming Guide 840C.

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

7–145

SINUMERIK 840C (IA)

Advertising