Explanation of display fields MSD 1st screen

Drive status

This display field describes the ramp-up and operating status of the digital drives.
This status is generated in the SERVO during start-up and then changed accor-
dingly in the display (SW 4: Drive MD 11008).
Possible data:

0

8

OFF

1

8

On (after the drive has returned status signal to SERVO)

2

8

On-line (communication possible)

3

8

Bootstrap (drive must be rebooted)

4

8

Connected (drive ramp-up completed)

5

8

Ready (drive under closed loop control, Power On)

Main spindle drive

This display field describes the actual MSD drive, i.e. the one which has been
selected using softkeys drive +/–.

Ramp-up phase

This display field contains the control word for the ramp-up control of the 611D
components and exists for each logical digital drive number (drive MD 11000).
The ramp-up state set by the SERVO is shown in the high byte and the state ack-
nowledged by the drive is shown in the low byte (see description drive status).

Possible information:

High byte

8

Set ramp-up status
(SERVO)

Values:

0 – 5

Low byte

8

Acknowledged ramp-up state (drive)

Values:

0 – 5

Possible display range: 0000 – 0505

Pulse enable

This display field contains the status of terminal 63/48 of the infeed/regenerative

(terminal 63/48)

feedback unit. (SW 3: drive MD 11.2 – pulse suppression for all drives – SW 4:
MD 1700.2).
Possible display range: off or on.

Drive enable

This display field contains the status of terminal 64 of the infeed/regenerative

(terminal 64/63)

feedback unit (SW 3: drive MD 11.6 – for all drives – SW 4: drive MD 1700.6).
Possible display range: off or on.

Pulse enable

This display field contains the status of terminal 663 (SW 3: drive MD 11.1 –

(terminal 663)

module-specific pulse suppression – SW 4: drive MD 1700.1).
Possible display range: off or on.

Pulse enable

This display field contains the status of the pulse enable PLC of the cyclic control

PLC setpoint

word 2 (drive MD 11005.7).
Possible display range: off or on.

Speed controller

This display field shows the condition of the speed controller enable NC of cyclic

enable setpoint

control word 2 (drive MD 11005.9).
Possible display range: off or on.

Setpoint parameter set

This display field contains the current set parameter set of cyclic control word 2
(drive MD 11005.0–2).
Possible display range: 0 – 7

Motor selection setpoint This display field contains the current motor type of cyclic control word 2 (drive

MD 11005.3).
Possible display range: Y or D (

8

star or delta)

CRC error

This display field contains the number of bus transmission errors between NC
and drive detected by the hardware (drive MD 11001).
Possible display range: 0000 – FFFF

4

MMC Area Diagnosis

4.3 Drive service displays for spindle (MSD) and axis (FDD) – as from SW 3)