Siemens SINUMERIK 840C User Manual

Page 998

Advertising
background image

09.95

12 Functional Descriptions

12.19.7 Retraction

The following individual sources are also available:

Axis/spindle-specific sources:

-

Retraction threshold FA/FS exceeded

-

DC link voltage warning threshold

-

Generator minimum speed limit

Activation of sources:

The user determines which of the possible axis sources initiate a retraction and which do
not in an axis-specific and spindle-specific MD byte NC MD 530* 596*.

Sources specific to channel/mode group and general sources:

-

Mode group stop of channel mode group

-

EMERGENCY STOP

Activation of sources:

The user determines which sources are active and which are not in a channel-specific MD
byte NC-MD 920*.

External sources via HW inputs:

A retraction process can be initiated from and external source (provided input is active) by
means of a mode group-specific input byte of the mixed I/O or CSB (can be defined by
means of MD).

Activation of input bits:

An MD byte NC-MD 922* is assigned to each channel; this byte is used to define which
input bits are active and which are not.

A retraction process is initiated if a low-level signal is present at an active input bit of the
mixed I/O, i.e. low-active inputs; 24 V must be applied to the active inputs before the
retraction is enabled.

Note:

Emergency retraction is only applied to axes that are under closed-loop control (i.e. controller
enable must be set).

© Siemens AG 1992 All Rights Reserved 6FC5197- AA50

12–223

SINUMERIK 840C (IA)

Advertising
This manual is related to the following products: