Siemens SINUMERIK 840C User Manual

Page 531

Advertising
background image

7 Drive Machine Data (SIMODRIVE Drive MD)

09.95

7.3.2 Drive MD (data description)

Controller enable

n

t

Case 1

MD 1403 = 0

t

I

t

n

Case 2

MD 1403 = X

I

Motor coasts out

Timer pulse suppression

1404

Default value

Lower input value

Upper input value

Units

100.0/5 000.0

0.0

100 000.0

ms

Active

at once

Input of timer for pulse suppression by drive. In the event of a fault (in generator braking mode
or with controller disabled), the control pulses for the power section transistors are suppressed
on the drive side after expiry of the time set in the adjustable timer. The pulses are
suppressed beforehand if the speed drops below the threshold set in machine data "Creep
speed pulse suppression" (MD 1403) before the timer expires. Monitoring takes place
sequentially on the drive and servo sides with variously adjustable timers. The default setting is
dependent on the motor type (FDD ˆ

=100, MSD ˆ

=5000) and is parameterized by the drive

configuration during start-up.

Note:

Under normal circumstances, shutdown is implemented sequentially on the drive and servo
sides, with variously adjustable timers (NC MD 156, NC MD 12240) and, in the event of a
fault, only on the drive side with timer MD 1404.

7–116

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)