6 NC Machine Data (NC MD), NC Setting Data (NC SD)

04.96

6.5 Spindle-specific MD (spindle data)

D

component

compensatory

controller

1)

489*

Default value

Lower input limit

Upper input limit

Units

0

0

16 000

1

Active on

Reset

These machine data are only used for the functionality "Electronic gearbox".

Together with the built-in test function (activated with NC MD 525*, bit 5), these machine data
can be used to set the control response of the PID compensatory controller.

A more detailed description of this function is to be found in the functional description for the
electronic gearbox.

Note: As from SW 4, for 8 gear stages

Time constant parallel model

1)

490*

Default value

Lower input limit

Upper input limit

Units

6 000

0

16 000

0.01 ms

Active on

Reset

This machine data is only used for the functionality "Electronic gearbox".

The parallel model must be set to the time constant of the position control loop of the following
spindle (time constant T = 1/servo gain).

If the value 16000 is entered in the machine data, the system automatically calculates the
actual servo gain factor and the time constant of the following spindle. However, this actual
servo gain factor is only stored internally, it cannot be looked at.

The value 16000 entered for the time constant is also automatically replaced by the value
derived by the control.

Note: As from SW 4, for 8 gear stages

Tolerance

range

synchronism

fine

1)

491*

Default value

Lower input limit

Upper input limit

Units

40

0

16 000

99999999 (SW5.4

and higher)

1 unit (MS)

Active on

Reset

Same description as for MD 492*
Note: As from SW 4, for 8 gear stages

Tolerance range synchronism coarse

1)

492*

Default value

Lower input limit

Upper input limit

Units

100

0

16 000

99999999 (SW5.4

and higher)

1 unit (MS)

Active on

Reset

This machine data is only used for the functionality "Electronic gearbox".

During LINK ACTIVE, the positional difference of the following spindle compared with the
leading axes/spindles is monitored by the tolerance range "Synchronism fine" and
"Synchronism coarse". If the positional difference is greater than the tolerance range, then the
corresponding PLC interface signal SYNCHRONISM FINE OR SYNCHRONISM COARSE is
set to 0 signal. With this interface signal it is therefore possible to determine the positional
synchronism of the following spindle.

More detailed information is given in the functional description for the electronic gearbox.

Note: As from SW 4, for 8 gear stages
_______

1)

As from SW 3

6–82

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)