Siemens SINUMERIK 840C User Manual

Page 162

Advertising
background image

09.95

Siemens AG 2001

All Rights Reserved

6FC5197–

j

AA50

5–34

SINUMERIK 840C (IA)

In the case of “Save all” the NQEC parameterization including the measured val-
ues from the NCK/servo are read out and stored in ASCII files under the selected
name.

In the case of “Load all”, the selected NQEC ASCII files are read in and stored as
boot files. A backup mechanism which is similar to that of TEA2-Load-all is imple-
mented which is able to recover the NQEC boot files automatically on a power
failure, emergency stop, if the hard disk is full or the abort key has been operated
etc.

New alarms for this function: 165051 to 165054.

5.8.2

2nd level: Configuring the individual
machine data areas (SW 3 and higher)

Drive machine data (TEA3)

Axis
(FDD)

Spindle
(MSD)

File
functions

NC machine data (TEA1)

General
NC MD

Geometry
motion

Channel

Axis

Spindle

Gearbox
interpol.

File
functions

Memory
config.

"

PLC machine data (TEA2)

I/O device
setting

Alarms
messages

PLC basic
data

User
MD

Tool
manage-
ment

Computer
link

File
functions

Cycle machine data (TEA4)

Central
cycle MD

Chan. dep.
cycle MD

File
functions

Interpolation compensation machine data (IKA1 – IKA3)

IKA con-
figuration

IKA curve
pointer

IKA error
points

File
functions

Explanation

On the 2nd level the file functions refer to the data of the individual machine data
areas. If the same file names are assigned to data records in different areas, they
appear on the first level (machine configuration) under one data selector and can
be loaded together from there.

5 Machine Data Dialog (MDD – as from SW 3)

5.8.2 2nd level: Configuring the individual machine data areas (as from SW 3)

Advertising