6 NC Machine Data (NC MD), NC Setting Data (NC SD)

09.95

6.2 General machine data (general data)

Keyswitch-protected R parameters

16, 17

Default value

Lower input limit

Upper input limit

Units

0

0

999 *

1 299 (as from SW 4)

Active

at once

Password-protected R parameters

14, 15

Active

at once

Appropriate specifications NC MD 14/15 and/or 16/17 make it possible to protect general and
channel-specific R parameters. Channel-specific specifications apply to all channels. The
parameter area defined in MD 14-15 is password-protected, the area defined by MD 16-17 is
protected via the keyswitch. The latter is effective only when bit 3 of NC MD 5005 is "1". If
exceeded, range MD 16-17 has priority.

Zero offset group (L 960)

18

Default value

Lower input limit

Upper input limit

Units

1

0

10

Active

MD 18 is of significance in conjunction with Siemens cycle L960 only, and may not be
modified.

Basic angle for nutating head

20

Default value

Lower input limit

Upper input limit

Units

0

0

±180 000

10

-3

deg

Active

in n. block

Please observe NC MD 5010 (5D tool length compensation).

Number of buffer pairs CP 315-1

24

Default value

Lower input limit

Upper input limit

Units

16

1

16

Active on

Power On

Number of buffer pairs CP 231-A

23

Active on

Power On

Number of buffer pairs CP 315-2

25

Active on

Power On

See Computer Link for details.

AP useful data length for CP 315-11-16

27

Default value

Lower input limit

Upper input limit

Units

234

0

256

254 (as from SW 4)

characters

Active on

Power On

AP useful data length for CP 231

26

Active on

Power On

AP useful data length for CP 315-2

28

Active on

Power On

See Computer Link for details.
_______

1)

As from SW 4 see Flexible Memory Allocation