6 NC Machine Data (NC MD), NC Setting Data (NC SD)

09.95

6.2 General machine data (general data)

Keyswitch-protected R parameters

16, 17

Default value

Lower input limit

Upper input limit

Units

0

0

999 *

1 299 (as from SW 4)

–

Active

at once

Password-protected R parameters

14, 15

Active

at once

Appropriate specifications NC MD 14/15 and/or 16/17 make it possible to protect general and
channel-specific R parameters. Channel-specific specifications apply to all channels. The
parameter area defined in MD 14-15 is password-protected, the area defined by MD 16-17 is
protected via the keyswitch. The latter is effective only when bit 3 of NC MD 5005 is "1". If
exceeded, range MD 16-17 has priority.

Zero offset group (L 960)

18

Default value

Lower input limit

Upper input limit

Units

1

0

10

–

Active

–

MD 18 is of significance in conjunction with Siemens cycle L960 only, and may not be
modified.

Basic angle for nutating head

20

Default value

Lower input limit

Upper input limit

Units

0

0

±180 000

10

-3

deg

Active

in n. block

Please observe NC MD 5010 (5D tool length compensation).

Number of buffer pairs CP 315-1

24

Default value

Lower input limit

Upper input limit

Units

16

1

16

–

Active on

Power On

Number of buffer pairs CP 231-A

23

Active on

Power On

Number of buffer pairs CP 315-2

25

Active on

Power On

See Computer Link for details.

AP useful data length for CP 315-11-16

27

Default value

Lower input limit

Upper input limit

Units

234

0

256

254 (as from SW 4)

characters

Active on

Power On

AP useful data length for CP 231

26

Active on

Power On

AP useful data length for CP 315-2

28

Active on

Power On

See Computer Link for details.
_______

1)

As from SW 4 see Flexible Memory Allocation