Activating the hard

The hard disk is configured with 5 Mbytes for user data. It is possible to use

disk options

more memory area if one or several hard disk options are activated. A hard disk

(up to SW 3 only)

option makes one of three areas of the hard disk available for additional user
data: an area of 5 Mbytes, an area of 10 Mbytes and an area of



20 Mbytes.

How to activate hard

First press the softkey PC START-UP/BACKUP in MMC area DIAGNOSIS under

disk options

menu item Setup/Add Options; Add user memory options.

Passwords

The following passwords have been allocated:

Menu item

1

MEMO1

2

MEMO2

3

MEMO3

When upgrading to software version >2, these options must first be enabled.

4.7

Customer UMS

General remarks

The customer UMS is created using the SW 800A workstation.

The UMS data are given the identifier “%UMS” and assigned to a language direc-
tory (e.g. ENGLISH) in the SERVICES area. Several UMS files with different na-
mes can exist side-by-side in the language directory. On POWER OFF and ON,
only the file with the name UMS can be loaded from the current language direc-
tory (set language) to the NCK.

An exact description of the operating sequences for loading data from an external
data storage device is to be found in the Operator’s Guide.

Up to SW 3

Up to SW 3 the customer UMS is enabled with an entry (ASMLEN) in the CON-
FIG file under Master control.

As from SW 4

With SW 4 and higher, please follow the description “Flexible memory configura-
tion”, see Section “Functional Descriptions”.

Note

The standard UMS is contained in the scope of supply of the SINUMERIK 840C.
If the user configures his own UMS, the standard UMS is not loaded in the NCK.

Menu 48,

The system setting may not allow you to leave menu 48 in the programming area

RECALL Key

using the RECALL key. If this happens, the setting in the BEDCONF file must be
changed. See the entry BAPPLMENMODLIST in the following figure:

23

i 2 2 15000

’0’ ’0’ ’0’ ’0’ ’0’ ’0’ ’0’ ’0’ ’0’ ’134’ ’48’ // BAPPLMENINDLIST

24

i 1 1 15000

// BAPPLIND

25

i 2 2 15001

’0’ ’0’ ’0’ ’0’ ’0’ ’0’ ’0’ ’0’ ’0’ ’0’ ’4’ // BAPPLMENMODLIST

26

i 1 1 15000

// BAPPLIND

27

i 2 2 15002

’0’ ’1’ ’0’ ’0’ ’0’ ’0’ ’0’ ’0’ ’2’ ’1’ ’1’ // BAPPLNCBERLIST

4 MMC Area Diagnosis

4.7 Customer UMS

Advertising
This manual is related to the following products: