DRIVE

GEN. RESET

SAVE

PLC

END GENERL

RESET MODE

09.95

Siemens AG 2001

All Rights Reserved

6FC5197–

j

AA50

2-5

SINUMERIK 840C (IA)

The configuration file for digital drives is deleted on the hard disk. This function
has no effect on analog drives.

Caution!
Pressing the DRIVE GEN. RESET softkey deletes the con-
tents of the BOOT FILE in the standard data. Any existing
DAC parameterization boot files (see Section 5) are also
deleted.

The user program currently in the PLC is copied onto the hard disk as
ANW_PROG file.

If the software is to be upgraded, this function must be executed before a forced
boot.

Terminates general reset mode. This function triggers a POWER-ON-RESET.

CAUTION! It is also possible to use the RECALL key for leaving the general reset
screen, but then no mode switchover is involved. The control consequently
remains in general reset mode (operating the machine, for example, is not
possible).

Note

S

The PLC-MDs are not valid until general reset mode has been terminated.

S

As from SW 4, the drives are booted.

S

Take into account flexible memory configuration function.

2 General Reset and Standard Start-Up

2.4 General reset (as from SW 3)