7 Drive Machine Data (SIMODRIVE Drive MD)

7.3.2 Drive MD (data description)

Relation between control word (MD 11004) and control word (MD 11002).

MD 1500

Status

MD 1500 > 0

MD 1500 > 0

MD 1500=0

Type of 1st filter

-

Low-pass

(MD 1501.0 = 0)

Band-stop

(MD 1501.0 = 1)

Inactive

(MD 1501.0 = 0 or 1)

Control word

MD 11004, bit 11

1

Status word

MD 11002, bit 11 = 1

Status word

MD 11002, bit 11 = 1

Status word

MD 11002, bit 11 = 1

Control word

MD 11004, bit 11

0

Status word

MD 11002, bit 11 = 0

Status word*

MD 11002, bit 11 = 1

Status word

MD 11002, bit 11 = 1

The 1st speed setpoint filter can be switched on/off via the control word (MD 11004, bit
11) only, if it is parameterized as low-pass (MD 1501, bit 0=0). It is not possible, if it has
been parameterized as band-stop (MD 1501, bit 0=1).

The status word (MD 11002, bit 11) indicates the active/inactive state of the 1st speed
setpoint filter only, if the filter is parameterized and selected as low-pass and is active
(MD 1550>0, MD 1501, bit 0=0).

Type speed setpoint filter

1501

Default value

Lower input limit

Upper input limit

Units

0000

0000

0303

Hex

Active

at once

Input of configuration of 2 speed setpoint filters. A selection of band-stop and low-pass filters
(PT2/PT1) are available. The adjustable filter parameters are entered in the appropriate
machine data.

Applications:

The set speed filter type "band-stop filter" is used to dampen axis-specific resonant
frequencies in the position control loop.

Depending on the requirement, the function "band-stop filter" can be set in three
configurations:
-

Simple band-stop filter, MD 1514/MD 1517 and MD 1515/MD 1518

-

Band-stop filter with settable damping of the amplitude response, other relevant
machine data MD 1516/MD 1519

-

Band-stop filter with settable damping of the amplitude response and raising or
lowering of the amplitude response after the blocking frequency, other relevant
machine data MD 1520/MD 1521.

Interpolation with speed setpoint stairs - the speed setpoints are output in the position
controller cycle which can be set to a much greater value than the speed controller cycle
(low-pass).

Low-pass/band-stop

1st filter

Bit 0

2nd filter

Bit 1

0

1

0

1

Low-pass (see MD 1502/1506/1507)

Band-stop (see MD 1514/1515/1516/1520)

Low-pass (see MD 1502/1508/1509)

Band-stop (see MD 1517/1518/1519/1521)

PT2/PT1 with low-

pass

1st filter

Bit 8

2nd filter

Bit 9

0

1

0

1

PT2 low-pass (see MD 1506/1507)

PT1 low-pass (see MD 1502)

PT2 low-pass (see MD 1508/1509)

PT1 low-pass (see MD 1503)

* Band-stop cannot be deactivated via control word

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

7–125

SINUMERIK 840C (IA)