10.94

7 Drive Machine Data (SIMODRIVE Drive MD)

7.1 611A main spindle drive machine data (MSD MD) (SW 3)

7

Drive Machine Data
(SIMODRIVE Drive MD)

7.1

611A main spindle drive machine data (MSD MD) (SW 3)

7.1.1

MSD MD input (SW 3)

The main spindle drive machine data are provided for the purpose of matching the main
spindle drives and the machine tool. If no setting values are specified by the machine
manufacturer or the user, then they must be carefully determined and optimized by the start-
up engineer. The setting values are input by means of menu selection (see section headed
"Machine Data Dialog").

7.1.2

MSD MD (data description - SW 3)

Speed setpoint

1

Default value

Lower output limit

Upper output limit

Units

0

rev/min

Active

at once

Display machine data for the present setpoint of the motor speed in rev/min.

Speed actual value

2

Default value

Lower output limit

Upper output limit

Units

0

rev/min

Active

at once

Display machine data for the present actual value of the motor speed in rev/min.

Motor voltage

3

Default value

Lower output limit

Upper output limit

Units

V

Active

at once

Display machine data for the present RMS value of the line-to-line motor voltage.

Capacity utilization

4

Default value

Lower output limit

Upper output limit

Units

%

Active

at once

Display machine data for utilization of the main spindle drive. The ratio between torque M

d

and

maximum torque M

dmax

is displayed up to rated speed n

rated

; the ratio between power P and

maximum power P

max

is displayed at speeds above the rated value.

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50