6 servo trace (sw 4) – Siemens SINUMERIK 840C User Manual

Page 685

Advertising
background image

09.95

Siemens AG 2001

All Rights Reserved

6FC5197–

j

AA50

9–64

SINUMERIK 840C (IA)

9.6

SERVO trace (SW 4)

Explanation

To supplement the start-up functions “DAC output” and “Measurement function”
implemented in SW 3, SW 4 includes a trace function with the following function-
ality:

S

4 trace buffers with 2048 values

S

Output of SERVO signals with symbolic signal selection

S

Graphic representation of recorded signal waveforms

S

Various trigger conditions for starting recording

S

Pre-trigger and post-trigger settings possible

S

File functions for storing and loading trace settings and measurement curves

The SERVO trace function is integrated on the highest menu tree level of the
drive servo start-up application since the 4 trace buffers offer 4 global resources
which can be applied to any NC axis or spindle (comparable to the 4 DAC chan-
nels of the mixed I/O module).

Selection

The SERVO trace display can be called by means of softkeys Diagnosis,
Start-up and Drive servo startup.

Fig. 9.35

Explanation

The measurement parameters relevant to the trace function can be set in this
display.

The field marked “Signal” is a pure output field which indicates the measured sig-
nal selected under softkey Selection meas.signal. The text “No signal” is the
default setting.

9 Drive Servo Start-Up Application (as from SW 3)

9.6 SERVO trace (SW 4)

Advertising