09.95

7 Drive Machine Data (SIMODRIVE Drive MD)

7.3.2 Drive MD (data description)

Damping current setpoint filter 4

1209

Default value

Lower input limit

Upper input limit

Units

1.0

0.05

5.0

Active

at once

Input of damping for current setpoint filter 4 (PT2 low-pass). The filter is activated via machine
data MD 1200 (No. current setpoint filters) and MD 1201 (Type current setpoint filter).

Block frequency current setpoint filter 1

1210

Default value

Lower input limit

Upper input limit

Units

3 500.0

1.0

7 999.0

Hz

Active

at once

Input of block frequency for current setpoint filter 1 (band-stop). When block frequencies of <
10 Hz are input, the filter is deactivated (proportional element with a gain of 1). The filter is
activated via machine data MD 1200 (No. current setpoint filters) and MD 1201 (Type current
setpoint filter).

Note:

The maximum block frequency input value is limited by the sampling frequency of the servo
control (MD 1000) (parameterization error).

MD 1210

2 x T

sampl. I-controller

1

T

sampl.

(MD 1000)

62.5

µ

s

125.0

µ

s

MD 1210

8000 Hz
4000 Hz

= MD 1000 [ s ]

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

7–105

SINUMERIK 840C (IA)