10.94

7 Drive Machine Data (SIMODRIVE Drive MD)

7.1.2 MSD MD (data description - SW 3)

Switching speed from M

d1

to M

d2

motor 1

50

Default value

Lower input limit

Upper input limit

Units

4 x rated motor

speed

0

Maximum motor

speed

rev/min

Active

at once

Input of speed at which switchover from the 1st torque limit (MD 39) to the 2nd torque limit
(MD 41) takes place. This switchover is implemented only if the appropriate bit has been set in
the PLC control word and the switchover speed set in MD 50 has been exceeded.

Transfer machine data to FEPROM

52

Default value

Lower input limit

Upper input limit

Units

0000

0000

0001

Hex

Active

at once

Note:

This machine data is not included in the machine data lists. During start-up in machine data
dialog, the machine data is set or altered as appropriate via the configuration setting.

The machine data can be saved from the RAM to the FEPROM by setting this machine data to
the value 1 H.

Control word

53

Default value

Lower input limit

Upper input limit

Units

0000

0000

FFFF

Hex

Active

at once

A range of control functions can be selected and altered by entering bit patterns in the control
word.

Selection of bits:

Not assigned

Bit 0

Ramp-function generator
rapid stop

Bit 1

0: The motor remains connected to the supply after

shutdown by the ramp generator rapid stop
function

1: The motor is isolated from the supply when the

speed drops below the internal n

min

speed value

after shutdown by the ramp generator rapid stop
function

Not assigned

Bits 2-3

Speed setpoint smoothing

Bit 4

0: Function is active only if the appropriate bit has

been set in the PLC control word

1: Function is always active

Not assigned

Bits 5-8

Inverter pulse frequency

Bits
9-10

Bit 9 = 0 and bit 10 = 0 : Selection of 3.44 kHz
Bit 9 = 0 and bit 10 = 1 : Selection of 4.95 kHz
Bit 9 = 1 and bit 10 = 0 : Selection of 6.60 kHz
Bit 9 = 1 and bit 10 = 1 : Selection of 8.11 kHz

Division interrupt
error message

Bit 11

0: Message is displayed
1: Message is concealed

Ramp-function generator
automatic control

Bit 12

0: Ramp-function generator automatic control active
1: Ramp-function generator automatic control

deactivated

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50