6 NC Machine Data (NC MD), NC Setting Data (NC SD)

6.7 Axis-specific MD 2 (axial data 2)

Application:
A gearbox grouping can be configured with the G401 command. If the type of link has not
been defined in the G401 command, the default value from MD 1456* is taken.

Example:

G401 X Y Z

X, Y: leading axes, Z: following axis, no link type.

If "No default" (MD 1456* = 0) has been entered and no link type has been entered in G401,
reset alarm "GI CONFIGURATION illegal" is triggered.

Time constant symmetrizing filter 3rd - 8th parameter set

(as from SW 4)

1460*-

1480*

Default value

Lower input limit

Upper input limit

Units

0

+0

1 000

0.1 ms

Active on
NC Stop

These MD have the same meaning as MD 392*, see also ”Functional Descriptions: Parameter
set switchover”.

Time constant setpoint filter 2nd - 8th parameter set

(as from SW 4)

1484*-

1508*

Default value

Lower input limit

Upper input limit

Units

0

0

1 000

0.1 ms

Active on

at once

These MD have the same meaning as MD 1272*, see also ”Functional Descriptions:
Parameter set switchover”.

Scaling factor max. velocity 2nd - 8th parameter set

(as from SW 4)

1512*-

1536*

Default value

Lower input limit

Upper input limit

Units

10 000

1

99 999 999

mm

inch degr.

–––– –––– ––––

min

min

min

Active in

channel of

mode group

in STOP

These MD have the same meaning as MD 256*, see also ”Functional Descriptions: Parameter
set switchover”.

Exact stop limit coarse 2nd - 8th parameter set

(as from SW 4)

1540*-

1564*

Default value

Lower input limit

Upper input limit

Units

40

+0

16 000

units (MS)

40

+0

99 999 999 (SW 4.4

and higher)

units (MS)

Active on
NC Stop

These MD have the same meaning as MD 204*, see also ”Functional Descriptions: Parameter
set switchover”.

©