12.93

7 Drive Machine Data (SIMODRIVE Drive MD)

7.2.2 FDD MD (data description - SW 3)

Bit 0

Internal error cannot be concealed

Bit 1

Not assigned

Bit 2

Measuring circuit error, phase current R

Bit 3

Measuring circuit error, phase current S

Bit 4

Measuring circuit error, position measuring system motor

Bit 5

Measuring circuit error, position measuring system motor (absolute track optical
encoder)

Bits 6-7

Not assigned

Bit 8

Zero monitoring position (zero mark) measuring system motor

Bits 9-14

Not assigned

Bit 15

Temperature power section shutdown

Note:

Power on 611D alarms can be acknowledged only via a hardware reset.

Concealable reset 611D alarms

1601

Default value

Lower input limit

Upper input limit

Units

0000

0000

FFFF

Hex

Active

at once

This machine data allows reset 611D alarms to be concealed or disabled. The alarm is active if
the appropriate bit = 0. All 611D alarms are activated as standard.

Bit 0

Configuration error cannot be concealed

Bits 1-7

Not assigned

Bit 8

Speed controller at fixed stop

Bits 9-13

Not assigned

Bit 14

Shutdown motor overtemperature

Bit 15

Not assigned

Note:

Reset 611D alarms can be acknowledged via a software reset.

Motor temperature warning limit

1602

Default value

Lower input limit

Upper input limit

Units

120

0

200

°C

Active

at once

Input of maximum permissible motor temperature. The temperature is detected by appropriate
sensors and evaluated in the drive. A message is transferred to the SERVO when the warning
limit is reached.

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50