7 Drive Machine Data (SIMODRIVE Drive MD)

7.1.2 MSD MD (data description - SW 3)

n

x

for n

act

< n

x

message motor 1

23

Default value

Lower input limit

Upper input limit

Units

6 000

0

Maximum motor

speed

rev/min

Active

at once

Input of response value for monitoring of the PLC status message n

act

< n

x

(see also MD

241).

Tolerance band for n

set

=

n

act

message

motor

1

27

Default value

Lower input limit

Upper input limit

Units

20

0

Rated speed

––––––––––––––-1

16

rev/min

Active

at once

Input of response value for the tolerance band of the PLC status message n

set

< n

act

(see

also MD 241). The tolerance band of the n

set

= n

act

response threshold can be defined in

machine data MD 27.

Diagnosis

28

Default value

Lower output limit

Upper output limit

Units

0000

0000

Hex

Active

at once

Output of diagnostic messages which do not cause tripping (pulse disable).

0008 H: Temperature sensor circuit interrupted or shorted
2000 H: Division interrupt: Error in calculation routines or incorrect entry of data

Speed limitation motor 1

29

Default value

Lower input limit

Upper input limit

Units

Maximum motor

speed

0

Maximum motor

speed

rev/min

Active

at once

Input of maximum motor speed (n

max

) = speed safety limit.

P-gain speed controller motor 1

31

Default value

Lower input limit

Upper input limit

Units

32.0

1.0

120.0

Active

at once

Input of P gain (K

p

) for the speed controller. The speed controller has a PI function which can

be set separately for eight gear stages.

Note:

A speed controller adaptation can be implemented only for gear stage 1 (see MD 203).

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50