10.94

7 Drive Machine Data (SIMODRIVE Drive MD)

7.1.2 MSD MD (data description - SW 3)

n

x

for n

act

< n

x

message motor 1

23

Default value

Lower input limit

Upper input limit

Units

6 000

0

Maximum motor

speed

rev/min

Active

at once

Input of response value for monitoring of the PLC status message n

act

< n

x

(see also MD

241).

Tolerance band for n

set

=

n

act

message

motor

1

27

Default value

Lower input limit

Upper input limit

Units

20

0

Rated speed

––––––––––––––-1

16

rev/min

Active

at once

Input of response value for the tolerance band of the PLC status message n

set

< n

act

(see

also MD 241). The tolerance band of the n

set

= n

act

response threshold can be defined in

machine data MD 27.

Diagnosis

28

Default value

Lower output limit

Upper output limit

Units

0000

0000

–

Hex

Active

at once

Output of diagnostic messages which do not cause tripping (pulse disable).

0008 H: Temperature sensor circuit interrupted or shorted
2000 H: Division interrupt: Error in calculation routines or incorrect entry of data

Speed limitation motor 1

29

Default value

Lower input limit

Upper input limit

Units

Maximum motor

speed

0

Maximum motor

speed

rev/min

Active

at once

Input of maximum motor speed (n

max

) = speed safety limit.

P-gain speed controller motor 1

31

Default value

Lower input limit

Upper input limit

Units

32.0

1.0

120.0

–

Active

at once

Input of P gain (K

p

) for the speed controller. The speed controller has a PI function which can

be set separately for eight gear stages.

Note:

A speed controller adaptation can be implemented only for gear stage 1 (see MD 203).

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50