8 PLC Machine Data (PLC MD)

8.5 PLC MD for the operating system (system bits)

6040

DL 20

DR 9

DL 9

DR 8

DL 8

DR7

DL 7

DR 6

DL 6

6041

DR 20

DR 11

DL 11

DR 10

DL 10

PLC MD

DB63

DW No.

Bit No.

7

6

5

4

3

2

1

0

Signal channel DB

Signal channel DB

Default value:

All bits default to 0

Bit = 0

The system software does not evaluate the bits in the corresponding interface
byte for operational messages.

Bit = 1

The system software evaluates the bits in the corresponding interface byte for
operational messages.

Notes:

1) The bit applies to all NC channels.
2) If the same bit is also set for error messages (PLC MD 6032, 6033), the PLC goes into the

Stop loop.

Sample application:

DB 10 D 6.8

1 signal operational message 6000;

PLC MD 6040.0=

1

See PLC Installation Section.