09.95

Siemens AG 2001

All Rights Reserved

6FC5197–

j

AA50

2-8

SINUMERIK 840C (IA)

2.6

Loading machine data (as from SW 3)

Note

Loading the machine data function takes several seconds and is accompanied by
the flashing message “Wait”.

Selection

The following softkeys must be pressed: Diagnosis, Startup, Machine data, File
functions:

Fig. 2.2

Procedure

Step

Operation

Comment

1

Activate the standard
data window with the

key

The window has a yellow border

2

Select STANDD_T or
STANDD_M

NC-MD

The MD in the NCK
area are cleared

3

SK Load from disk

and assigned stan-
dard values

4

Select STANDARD

dard values

5

SK Load from disk

PLC MD, cycl. MD

Initial start-up

On initial start-up (state as supplied from Siemens), no files are available in the
“User data” window(see Fig.).

Subsequent start-up

On subsequent start-up, user files from the “User data” window can be loaded
instead of the files STANDD_T, STANDD_M, STANDARD in the “Standard data”
window.

Make sure that no communication is taking place with the digital drive systems. If
the user file contains drive data (TEA3), you must acknowledge the drive-specific

2 General Reset and Standard Start-Up