Siemens SINUMERIK 840C User Manual

Page 613

Advertising
background image

09.95

8 PLC Machine Data (PLC MD)

8.5 PLC MD for the operating system (system bits)

6044

DL 22

DR 4

DL 4

DR 3

DL 3

DR 2

DL 2

DR 1

DL 1

6045

DR 22

DR 8

DL 8

DR 7

DL 7

DR 6

DL 6

DR 5

DL 5

6046

DL 23

DR 12

DL 12

DR 11

DL 11

DR 10

DL 10

DR 9

DL 9

6047

DR 23

DL 16

DR 15

DL 15

DR 14

DL 14

DR 13

DL 13

PLC MD

DB63

DW No.

Bit No.

7

6

5

4

3

2

1

0

Signal DB 58

Signal DB 58

Signal DB 58

Signal DB 58

Default value:

All bits default to 0

Bit = 0

The system software does not evaluate the bits in the corresponding interface
byte for operational messages.

Bit = 1

The system software evaluates the bits in the corresponding interface byte for
operational messages.

Note:

If the same bit is also set for error messages (PLC MD 6036 to 6039), the PLC goes into the
Stop loop.

Sample application:

DB 58 D 5.1

1 signal operational message 9073;

PLC MD 6045.1 = 1

© Siemens AG 1992 All Rights Reserved 6FC5197- AA50

8–21