6 NC Machine Data (NC MD), NC Setting Data (NC SD)
12.93
6.6.1 General MD bits (general bits)
Execution from external
7
6
5
4
3
2
1
0
Bit No.
NC MD
5148
0
1
0
0
0
1
1
0
7
6
5
4
3
2
1
0
Bit No.
NC MD
5149
0
1
0
0
1
1
0
0
7
6
5
4
3
2
1
0
Bit No.
NC MD
5150
0
1
0
1
0
0
1
0
7
6
5
4
3
2
1
0
Bit No.
NC MD
5151
0
1
0
1
1
1
1
1
These machine data are valid only for ”Execution from external”via the computer link interface.
In the 4 bytes, the ”Logical partner receiver” is entered to which the request message is
forwarded when starting the ”Execution from external” function.
These values are entered as ASCII values
The default setting is as described above and is referred to in ASCII as ”FLR_”.