8 standard installation short version (up to sw 2) – Siemens SINUMERIK 840C User Manual

Page 42

Advertising
background image

09.95

Siemens AG 2001

All Rights Reserved

6FC5197–

j

AA50

2-11

SINUMERIK 840C (IA)

2.8

Standard installation short version (up to SW 2)

As from software version 3, machine data dialog is used for
standard installation and start-up.
See Machine Data Dialog Section (MDD).

Operation

The following sequence must be followed for standard SINUMERIK 840C installa-
tion and start-up:

1. The control and the external components must be connected as described in

the SINUMERIK 840C Interface Description.

2. Cabling and electrical operating conditions must be checked as defined in the

Interface Description, Part 2.

3. Observe Section 1 of the Installation Guide carefully.

4. Installation of the axes and spindles, including the speed controller.

5. Servo disable set at the hardware level for all axes and spindles.

6. All input/output modules and handwheels connected.

7. NC MD and PLC MD entered.

8. All data, in particular NC MD and PLC MD, must be checked for validity.

9. Enclose the installation checklist in the completed log book.

Password

Data and files are protected against unauthorized access with the password.

The MMC and NCK areas are each protected with their own password.

Selecting a password
in the NCK area

DIAGNOSIS

NC

DIAGNOSIS

NC

START-UP

ENTER

PASSWORD

2 General Reset and Standard Start-Up

2.8 Standard installation short version (up to SW 2)

Advertising