Dl 121, Dr 121, Dl 125 – Siemens SINUMERIK 840C User Manual

Page 1014: Dr 125, Dl 237, Dr 237

Advertising
background image

12.93

12 Functional Descriptions

12.22.2 Functional description

7

6

5

4

3

2

1

0

Bit No.

Byte no.

Axis1

DL

121

Cam

4+

Cam

4–

Cam

3+

Cam

3–

Cam

2+

Cam

2–

Cam

1+

Cam

1–

Axis1

DR

121

Axis2

DL

125

Cam

4+

Cam

4–

Cam

3+

Cam

3–

Cam

2+

Cam

2–

Cam

1+

Cam

1–

Axis2

DR

125

:
:

Axis30

DL

237

Cam

4+

Cam

4–

Cam

3+

Cam

3–

Cam

2+

Cam

2–

Cam

1+

Cam

1–

Axis30

DR

237

Signals from axis

15

14

13

12

11

10

9

8

The user can also output the cam signals in the IPO cycle via a digital output byte of the
MIXED I/O. The cam signals are assigned to a MIXED I/O output byte via NC MD 311.

7

6

5

4

3

2

1

0

Bit No.

Byte No.

1 or 2

Cam

4+

Cam

4–

Cam

3+

Cam

3–

Cam

2+

Cam

2–

Cam

1+

Cam

1–

MIXED I/O

© Siemens AG 1992 All Rights Reserved 6FC5197- AA50

12–239

SINUMERIK 840C (IA)

Advertising