Siemens SINUMERIK 840C User Manual

Page 427

Advertising
background image

7 Drive Machine Data (SIMODRIVE Drive MD)

10.94

7.1.2 MSD MD (data description - SW 3)

Input of shift factor DAC1 for analog output. The top 8 bits from a 16-bit wide memory location
are output. This machine data specifies how often the value must be shifted to the left
beforehand. A shift by one position corresponds to a multiplication by 2, i.e. the shift factor
allows multiplication by the power of two 2

shift factor

. The maximum gain which can be obtained

in this way is 32768 (only the last bit is evaluated).

Offset DAC1

80

Default value

Lower input limit

Upper input limit

Units

0000

FF80

007F

Hex

Active

at once

Note:

This machine data is not included in the machine data lists. The DACs are configured in the
course of the drive servo start-up procedure for diagnostic purposes.

Input of an offset value for DAC1 which is added to the value prior to analog output.

Power section code number

95

Default value

Lower input limit

Upper input limit

Units

7

6

12

Active

Power On

Note:

This machine data is not included in the machine data lists. During start-up in machine data
dialog, the machine data is set or altered as appropriate via the configuration setting.

Input of code number for the power section used.

Converter table:

Code number

Power section order no.

Current

6

6SN1135-1DA1 -0CA0

24/32/32A

7

6SN1135-1DA1 -0DA0

30/40/51A

8

6SN1135-1DA1 -0GA0

45/60/76A

9

6SN1135-1DA1 -0EA0

60/80/102A

10

6SN1135-1DA1 -0FA0

85/110/127A

7–12

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)