6 NC Machine Data (NC MD), NC Setting Data (NC SD)

12.93

6.6.1 General MD bits (general bits)

7

6

5

4

3

2

1

0

Bit No.

NC MD

5060

5061

5062

to

5069

G function for transformation selection (1st block)

Axis name (1st block)

Transformation channel number (1st block)

Default values

MD 5060, 5061:

All bits default to 0

"

MD 5062 to 5069:

All bits default to 1

MD for 1st TRANSFORMATION BLOCK.
MD 5060

Channel numbers 1 to 4
Example for channel 3

0000 0011

MD 5061

G function for Transmit

G131

0001 0001

G231

0010 0001

G331

0011 0001

MD 5062-5069

Axis name according to code table, see MD 568*

The default values must be retained if Transformation (option 6FC5 150-0AD04-0AA0) is not
used. Illegal MD results in alarm 3087.

Active:

All Transmit MDs become active on Power On or on a warm restart

For a detailed description, see Section 13.4.

7

6

5

4

3

2

1

0

Bit No.

NC MD

5070

5071

5072

to

5079

G function for transformation selection (2nd block)

Axis name (2nd block)

Transformation channel number (2nd block)

See MD 5060
MD for 2nd TRANSFORMATION BLOCK.