3 format for log masks – Siemens SINUMERIK 840C User Manual

Page 91

Advertising
background image

09.95

Siemens AG 2001

All Rights Reserved

6FC5197–

j

AA50

4–28

SINUMERIK 840C (IA)

BT_Name

FlexOS name of the operator panel interface.
For operation without the operator panel enter “” only. The default setting is
“SER” (upper case mandatory).

PROTLEN1

This defines the number of messages that are entered in alarm log 1.

PROTLEN2

This defines the number of messages that are entered in alarm log 2.

FLUSHLEN1

Maximum number of messages buffered for the alarm log (lost on voltage
failure).

FLUSHLEN2

Maximum number of messages buffered for the service log (lost on voltage
failure).

4.4.2.3

Format for log masks

Note

As from SW3, the alarms are configured in the ‘MELDATTR’ and ‘MELDTEXT’
files. For configuring notes, please refere to Interface, Part 1.

You can define which messages are to be entered in the log by specifying the
attributes of these messages and the limitations which apply to them. Each mes-
sage attribute is abbreviated to its initial letter (Number, Klasse = class), Type,
Priority). The limitations are specified using the characters ‘<’, ‘>’, ‘=’ and ‘–’.
Examples:

N > 1000

Messages with a number greater than 1000 are logged

P < 5

Messages with a priority less than 5 are logged

P = 0

Messages with a priority of 0 are logged

N50 – 100

Messages with a priority between 50 and 100 are logged.

A ‘PROTMASK’ line can comprise several such limitations, which are then inter-
preted as logically ANDed. If several ‘PROTMASK’ lines (up to 5) are specified
for one log they are logically ORed.

The values of type and class of a message are coded as follows:

Type of alarm

Coding

Power-on alarm

0

Reset larm

1

Cancel alarm

2

PLC alarm

3

PLC message

4

NCK comment

5

1)

Class

Coding

NCK

0

System / master control

1

Services

2

Diagnosis

3

Programming

4

User (OEM)

6

Table 4.1 Coding of message types and classes

4 MMC Area Diagnosis

4.4.2 Configuration file CONFIG

1) Up to SW2

Advertising
This manual is related to the following products: