10.94

12 Functional Descriptions

12.18.5 Curve-gearbox interpolation (CGI) (SW 4 and higher)

Link types of GI/IKA link structures

Link

type

GI/IKA link types

FA position

input is linked

to

Output of link branch is

connected to

GI link branch with:

K1

Setpoint position link
(and possibly actual
position link via com-
pensatory controller)

Setpoint
position of
leading
address

Setpoint position input
of following address

K2

Actual position and
actual velocity link

Actual
position of
leading
address

Setpoint position input
of following address

K3

Setpoint position link
"simulated leading
address"

Setpoint
position of
leading
address

Setpoint position input
of following address

K4

Actual position and
setpoint velocity link

Actual
position of
leading
address

Setpoint position input
of following address

GI link branch with:

IKA input A

supplied by:

IKA input B supplied by:

K11 Setpoint link

Setpoint
position of
leading
address

Specification of
weighting factor in
G402/3 command
(I, J)

Setpoint position input
of following address

K12 Actual value link

Actual
position of
leading
address

Specification of
weighting factor in
G402/3 command
(I, J)

Setpoint position input
of following address