Siemens SINUMERIK 840C User Manual

Page 83

Advertising
background image

09.95

Siemens AG 2001

All Rights Reserved

6FC5197–

j

AA50

4–20

SINUMERIK 840C (IA)

Parking axis setpoint

This display field shows the status of parking axis of cyclic control word 1
(drive MD 11004.1)
Possible display range: off or on

Travel to fixed stop

This display field contains the status of Travel to fixed stop of cyclic status word 2

actual

(drive MD 11003.13)
Possible display range: off or on

Speed setpoint

This display field contains the status of speed setpoint smoothing of cyclic status

smoothing actual value

word 1 (drive MD 11002.11).

Ramp-function

This display field contains the status of ramp-function generator rapid stop of

generator rapid

cyclic status word 1 (drive MD 11002.9).

stop actual value

Possible display range: off or on

V/F mode

This display field contains the status of V/F mode of cyclic status word 2
(drive MD 11003.12).
Possible display range: off or on

2nd torque limit

This display field shows the status of 2nd torque limit of cyclic status word 1

actual value

(drive MD 11002.10).
Possible display range: off or on

Integrator inhibit

This display field shows the status of the integrator inhibit of cyclic status word 1

actual value

(drive MD 11003.6).
Possible display range: off or on

Motor temperature

This display field shows the state of the motor temperature warning

warning

(drive MD 11006.14)
Possible display range: off or on

Heat sink temperature

This display field shows the state of the heat sink temperature warning

warning

(drive MD 11006.15)
Possible display range: off or on

Ramp-up completed

This display field shows the current status of the message Ramp-function

(SW 4)

procedure completed (drive MD 11007.0).

IM

d

I < M

dx

(SW 4)

This display field shows the current status of the message IM

d

I < M

dx

(drive MD

11007.1).

In

act

I < n

min

(SW 4)

This display field shows the current status of the message In

act

I < n

min

(drive MD

11007.2).

In

act

I < n

x

(SW 4)

This display field shows the current status of the message In

act

I < n

x

(drive MD

11007.3).

n

set

< n

act

(SW 4)

This display field shows the current status of the message n

set

< n

act

(drive MD

11007.4).

Variable message

This display field shows the current status of the message Variable message

function (SW 4)

function (drive MD 11007.5).