6 NC Machine Data (NC MD), NC Setting Data (NC SD)

09.95

6.7.1 Axis-specific MD bits 2 (axial bits 2)

7

6

5

4

3

2

1

0

Bit No.

NC MD

1820*

Contour

monitoring

not active

Pulse

encoder

monitoring

on

No. of

encoder

pulses (611D)

2nd meas.

system (as

from SW 3)

Second meas.

system with

external zero

mark (as from

SW 3)

No. of

encoder

pulses (611D)

1st meas.

system (as

from SW 3)

First meas.

system with

external zero

mark (as from

SW 3)

Zero

monitoring

on

Setpoint

smoothing

on

Default value:

0000 0000

Bit 7 Bit 7=1 The dynamic contour monitoring function is switched off.

Bit 6

Pulse encoder monitoring on

Bit 6=1 Monitoring is carried out to determine how many directional changes have

occurred between two measuring clock pulses. If too many directional changes
are detected, alarm 140* is triggered (also see description of alarm 140*).

Bit 6=0 Monitoring switched off.

Bit 5

Digital drives only:

Bit 5=0 Number of encoder intervals between two reference marks of the second

measuring system is a multiple of 16

Bit 5=1 Number of encoder intervals between two reference marks of the second

measuring system is a multiple of 10

Bit 4

Digital drives only:

Bit 4=0 Second measuring system without external zero mark (BERO)
Bit 4=1 Second measuring system without external zero mark (BERO)

1)

Bit 3

Digital drives only:

Bit 3=0 Number of encoder intervals between two reference marks of the first

measuring system is a multiple of 16

Bit 3=1 Number of encoder intervals between two reference marks of the first

measuring system is a multiple of 10

Bit 2

Digital drives only:

Bit 2=0 First measuring system without external zero mark (BERO)
Bit 2=1 First measuring system with external zero mark (BERO)

1)

Bit 1

Zero monitoring on

Bit 1=1 Monitoring is performed to detect whether pulses have been lost between two

zero mark passes (do not use for distance-coded reference marks).
If so, alarm 144* is triggered (also see description of alarm 144*).

Bit 1=0 Monitoring switched off

Bit 0

Setpoint smoothing on

Bit 0=1 The setpoint smoothing filter parameterized in MD 1272* is switched on.

_______

1)

Speed-related errors in referencing occur with reference point approach with external zero mark (BERO).

This is caused by the delay time of the optocoupler at the input.

To avoid such errors in referencing, the maximum velocity must be limited.

6–188

©