Siemens SINUMERIK 840C User Manual

Page 610

Advertising
background image

8 PLC Machine Data (PLC MD)

09.95

8.5 PLC MD for the operating system (system bits)

6035

DR 17

DR k+3

DL k+3

PLC MD

DB63

DW No.

Bit No.

7

6

5

4

3

2

1

0

Alarm DB 32

Default value:

All bits default to 0

K = 0, 4, 8, 12, ... 116 (1st to 30th axis)

Bit = 0

The system software does not evaluate the bits in the corresponding interface
byte for error messages.

Bit = 1

The system software evaluates the bits in the corresponding interface byte for
error messages.

Notes:

1) The bit applies to all axes.
2) If the identical bit is also set for operational messages (PLC MD 6043), the PLC goes into

the Stop loop.

Sample application:

DB 32 D 3.3

1 signal error message 8211;

PLC MD 6035.1=

1

See PLC Installation Section.

6036

DL 18

DR 4

DL 4

DR 3

DL 3

DR 2

DL 2

DR 1

DL 1

6037

DR 18

DR 8

DL 8

DR 7

DL 7

DR 6

DL 6

DR 5

DL 5

6038

DL 19

DR 12

DL 12

DR 11

DL 11

DR 10

DL 10

DR 9

DL 9

6039

DR 19

DL 16

DR 15

DL 15

DR 14

DL 14

DR 13

DL 13

PLC MD

DB63

DW No.

Bit No.

7

6

5

4

3

2

1

0

Alarm DB 58

Alarm DB 58

Alarm DB 58

Alarm DB 58

Default value:

All bits default to 0

Bit = 0

The system software does not evaluate the bits in the corresponding interface
byte for error messages.

Bit = 1

The system software evaluates the bits in the corresponding interface byte for
error messages.

Note:

If the identical bit is also set for operational messages (PLC MD 6044-6047), the PLC goes
into the Stop loop.

Sample application:

DB 58 D 3.10

1 signal error message 9034;

PLC MD 6039.4 =

1

8–18

© Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)

Advertising