6 NC Machine Data (NC MD), NC Setting Data (NC SD)

09.95

6.7 Axis-specific MD 2 (axial data 2)

f: Pulse multiplication EXE/611D/HMS 1st measuring system

1116*

Default value

Lower input limit

Upper input limit

Units

1

1

128

1)

512

2)

Active on

Power On

Warm restart

MD 1116* is used to set the multiplication factor for the actual position pulses when using the
6FX 1145-6B... HMS measuring-circuit module. On Power On, the NC software checks to see
whether an HMS measuring-circuit module has been inserted; only when this is the case does
MD 1116* take effect.

The following multiplication factors can be specified:

HMS:

1, 2, 4, 8, 16, 32, 64, 128

611D/PCU:

1, 2, 4, 8, 16, 32, 64, 128, 256, 512

Measuring system resolution = measuring system x 4 x MD 1116*

Note

This MD also has an effect when the measuring system of the digital drive (611-D) is used.

D component feedforward control

1124*

Default value

Lower input limit

Upper input limit

Units

0

0

1 000

0.1 %

Active on

NC Stop

Active:

When activating feedforward control

MD 1124* is used to modify the setpoint speed in proportion to acceleration. Where position
control cycles are < 1 ms, the rise process can be accelerated even more by the D
component. It should not be used with larger sampling intervals.

Note:

As from SW 4, for 8 parameter blocks

Feedforward control factor 3rd parameter set

3)

1140 *

Default value

Lower input limit

Upper input limit

Units

0

+0

1 000

0.1%

Active on

NC Stop

This MD has the same meaning as MD 312*, see also functional description of parameter set
switchover.

_______

1)

As from SW 2

2)

As from SW 3

3)

As from SW 4

6–160

©