Siemens SINUMERIK 840C User Manual

Page 217

Advertising
background image

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

09.95

6.3 Channel-specific MD (channel data)

Reset state G group

108*-122*

Default value

Lower input limit

Upper input limit

Units

see below

see table of input

values

see table of input

values

–

Active in block

prior

to

decodg

The reset state for G groups 1, 3, 6, 8, 12, 15 and 25 may be defined on a channel-specific
basis.

Only those G functions shown in the table below may be specified in NC MD 108* to 122* for
the relevant G group.

The reset state for G group 9 (G70/G71) is defined together with the input resolution in
NC MD 5002.

Default value

T

M

G group

108*

1

1

1

110*

18

17

3

112*

54

54

6

114*

64

60

8

116*

0

0

9

118*

95

94

12

120*

150

150

15

122*

450

450

1)

25

Table of input values

Internal

G group

G functions

0

00

MD

01

M/T

MD

10

MD

11

MD

02

MD

03

MD

33

MD

34

MD

35

MD

06

MD

12

MD

13

MD

36

MD

1

09

2

17

M

MD

18

T

MD

19

MD

16

3

40

M/T

41

42

4

53

5

54

M/T

MD

55

MD

56

MD

57

MD

6

04

25

26

58

59

92

74

7

60

M

MD

63

MD

64

T

MD

62

MD

8

70

71

_______

1)

As from SW 2

6–32

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)

Advertising