6 NC Machine Data (NC MD), NC Setting Data (NC SD)

09.95

6.3 Channel-specific MD (channel data)

Reset state G group

108*-122*

Default value

Lower input limit

Upper input limit

Units

see below

see table of input

values

see table of input

values

Active in block

prior

to

decodg

The reset state for G groups 1, 3, 6, 8, 12, 15 and 25 may be defined on a channel-specific
basis.

Only those G functions shown in the table below may be specified in NC MD 108* to 122* for
the relevant G group.

The reset state for G group 9 (G70/G71) is defined together with the input resolution in
NC MD 5002.

Default value

T

M

G group

108*

1

1

1

110*

18

17

3

112*

54

54

6

114*

64

60

8

116*

0

0

9

118*

95

94

12

120*

150

150

15

122*

450

450

1)

25

Table of input values

Internal

G group

G functions

0

00

MD

01

M/T

MD

10

MD

11

MD

02

MD

03

MD

33

MD

34

MD

35

MD

06

MD

12

MD

13

MD

36

MD

1

09

2

17

M

MD

18

T

MD

19

MD

16

3

40

M/T

41

42

4

53

5

54

M/T

MD

55

MD

56

MD

57

MD

6

04

25

26

58

59

92

74

7

60

M

MD

63

MD

64

T

MD

62

MD

8

70

71

_______

1)

As from SW 2

6–32

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50