6 NC Machine Data (NC MD), NC Setting Data (NC SD)

07.97

6.10 MDs for flexible memory configuration

Memory configuration of NC module as from SW 4

60011

Default value

Lower input limit

Upper input limit

Units

0

Byte

Active

after SK

"Reconfigure

memory"

Machine data reserved by the system.

Load cap. of NC CPU (as from SW 5)

60012

Default value

Lower input limit

Upper input limit

Units

0

-

100

%

Active

At once

This machine data is used simply to indicate the CPU loading. For a description, refer to the
section entited ”Installation of axis and spindle”.

Memory for real axes (as from SW 5)

60013

Default value

Lower input limit

Upper input limit

Units

15

15

30

approx. 16 KB/axis

Active

Power On

This MD is used to define the memory for real axes (> 15). If the user has defined more real
axes than memory is available, alarm 71 is displayed.

Number of memory blocks for drive software

(as from SW 6)

60014

Default value

Lower input limit

Upper input limit

Units

0

0

6

96 Kbytes

Active

Power On

Memory for drive software MSD/FDD 0/2/3/4/6 blocks of 96 Kbytes each, see also machine
data 60003 and 60004.

Channel 1 to channel 6 as from SW 4

6100*

Default value

Lower input limit

Upper input limit

Units

23

0

3 450

1 block buffer

Active

after SK

"Reconfigure

memory"

This MD is used to define channel-specifically the maximum number of part program blocks
that can be predecoded during execution.