Siemens SINUMERIK 840C User Manual

Page 442

Advertising
background image

10.94

7 Drive Machine Data (SIMODRIVE Drive MD)

7.1.2 MSD MD (data description - SW 3)

Reduction factor reset time motor 1

202

Default value

Lower input limit

Upper input limit

Units

100

1

200

%

Active

at once

Input of reset time reduction factor for the upper adaptation speed. This machine data contains
the multiplication factor for the reset time characteristic (see diagram MD 203).

Selection adaption speed controller motor 1

203

Default value

Lower input limit

Upper input limit

Units

0

0

7

Active

at once

Input of activation point for speed controller adaption. The diagram shows how the individual
machine data influence the speed characteristic.

n

K

P

, T

N

MD 199/MD 286

n

1

(MD 195/MD 283)

Lower speed

MD 202/MD 289

MD 201/MD 288

MD 198/MD 285

MD 31/MD 265

n

2

(MD 196/MD 284)

Upper speed

MD 32/MD 266

0:

No speed controller adaption

1:

No function assigned at present

2:

Speed controller adaption activated

3:

No function assigned at present

Note:

The speed controller adaption function is available only for operation in gear stage 1.

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

7–27

SINUMERIK 840C (IA)

Advertising