7 Drive Machine Data (SIMODRIVE Drive MD)

12.93

7.2.2 FDD MD (data description - SW 3)

Note:

Under normal circumstances, shutdown is implemented sequentially on the drive and servo
sides, with variously adjustable timers (NC-MD 156, NC-MD 12240) and, in the event of a
fault, only on the drive side with timer MD 1404.

Monitoring speed motor

1405

Default value

Lower input limit

Upper input limit

Units

110

100

110

%

Active

at once

Input of maximum permissible speed setpoint as a limit value for the speed actual value
monitor. The machine data "Maximum motor speed" (MD 1401) is applied as the reference
value.

P-gain speed controller

1407

Default value

Lower input limit

Upper input limit

Units

0.3

0

100 000

Nm/s

-1

Active

at once

Input of P-gain of the speed control loop in the lower speed range (n < lower speed threshold
in MD 1411). The P-gain values in the lower speed range (MD 1407) and the upper speed
range (MD 1408) are not subject to any mutual restrictions. See machine data "Adaptation
lower speed threshold" (MD 1411) for diagram.

Note:

Before the P-gain is set to 0, the associated integral-action component (MD 1409) must be
deactivated to maintain controller stability.

MD 1407 is active over the entire speed range when the "Speed controller adaptation" is
deactivated (MD 1413 = 0).

P-gain upper adaptation speed

1408

Default value

Lower input limit

Upper input limit

Units

0.3

0

100 000

Nm/s

-1

Active

at once

Input of P-gain of the speed control loop in the upper speed range (n > upper speed threshold
in MD 1412). The P-gain values in the lower speed range (MD 1407) and the upper speed
range (MD 1408) are not subject to any mutual restrictions. See machine data "Adaptation
lower speed threshold" (MD 1411) for diagram.

Note:

Before the P-gain is set to 0, the associated integral-action component (MD 1410) must be
deactivated to maintain controller stability.

MD 1408 is not active when the "Speed controller adaptation" is deactivated (MD 1413 = 0).

7–64

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50