5 permissible resolution combinations – Siemens SINUMERIK 840C User Manual

Page 698

Advertising
background image

10 Axis and Spindle Installation

03.95

10.2.5 Permissible resolution combinations

10.2.5 Permissible resolution combinations

Permissible resolution combinations

Input resolution, display resolution and position control resolution can be defined in any
combination within certain limits (see the following two tables). Please note that a factor of
max. 200 between input resolution and position control resolution for all axes together is
possible.

Example:

Input resolution

10

-4

mm or degrees

Position control resolution rotary axis

0.5 . 10

-4

degrees

Position control resolution machining axes

0.5 . 10

-3

mm

Position control resolution loader axes

0.5 . 10

-2

mm

Permissible combinations of position control resolution and input resolution

Unit

system

Position control

resolution

Input resolution

10

-2

[mm]

[degr.]

10

-3

[mm]

[degr.]

10

-4

[mm]

[degr.]

10

-5

[mm]

[degr.]

10

-3

[inch]

[degr.]

10

-4

[inch]

[degr.]

10

-5

[inch]

[degr.]

10

-6

[inch]

[degr.]

mm

0.5 x 10

-2

[mm][degr.]

xy

x

x

-

x

x

x

-

mm

0.5 x 10

-3

[mm][degr.]

xy

xy

2)

x

-

x

x

x

-

mm

2 x 10

-4

[mm]

x

x

x

x

-

-

x

x

mm

0.5 x 10

-4

[mm][degr.]

xy

xy

xy

x

-

-

x

x

mm

0.5 x 10

-5

[degr.]

y

y

y

y

-

-

-

-

inch

0.5 x 10

-3

[inch][degr.]

x

x

-

-

xy

x

x

-

inch

0.5 x 10

-4

[inch][degr.]

x

x

-

-

xy

xy

x

-

inch

2 x 10

-5

[inch]

x

x

x

x

x

x

x

x

inch

0.5 x 10

-5

[inch][degr.]

x

x

x

x

xy

xy

xy

x

x

...

linear axes only

y

...

rotary axes only

xy ...

linear and rotary axes

...

linear and rotary axes illegal

2)

standard machine data

Note:

Excessive differences between position control resolution and input resolution ought to be
avoided. For example, an input resolution of 10

-2

mm together with a position control resolution

of 0.5 - 10

-5

mm does not make sense since one geometry resolution unit equals 1000

position control resolution units.

If the units of both position control and input resolution belong to the same unit system (metric,
inches, degrees), the display resolution and the position control resolution must be equal (see
table above).

If the units of the position control and input resolution do not belong to the same unit system,
the display resolution must be set according to the table above.

As a matter of principle, the same unit system must be used for the display resolution and the
input resolution.

Note:

As from SW 4, the position control and display resolution for the rotary axes must not exceed
the input resolution.

_______

1)

Bit "High-resolution rotary axis" must be set for rotary axes. For input resolution 10

-4

, otherwise alarm

message 4 "System of units illegal" is output.

10–8

© Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)

Advertising