7 Drive Machine Data (SIMODRIVE Drive MD)

10.94

7.1.2 MSD MD (data description - SW 3)

Programmable message 2

242

Default value

Lower input limit

Upper input limit

Units

3

1

20

Active

at once

A function can be assigned to programmable message 2 in this machine data.

The default setting corresponds to M

d

> M

dx

(see MD 241 for other settings).

Programmable message 3

243

Default value

Lower input limit

Upper input limit

Units

1

1

20

Active

at once

A function can be assigned to programmable message 3 in this machine data.

The default setting corresponds to n

act

< n

min

(see MD 241 for other settings).

Programmable message 4

244

Default value

Lower input limit

Upper input limit

Units

4

1

20

Active

at once

A function can be assigned to programmable message 4 in this machine data.

The default setting corresponds to n

act

< n

x

(see MD 241 for other settings).

Programmable message 5

245

Default value

Lower input limit

Upper input limit

Units

20

1

20

Active

at once

A function can be assigned to programmable message 5 in this machine data.

The default setting corresponds to variable relay function 1 (MD 185, see MD 241 for other
settings).

Programmable message 6

246

Default value

Lower input limit

Upper input limit

Units

7

1

20

Active

at once

A function can be assigned to programmable message 6 in this machine data.

The default setting corresponds to variable relay function 2 (MD 190, see MD 241 for other
settings).