Siemens SINUMERIK 840C User Manual

Page 550

Advertising
background image

09.95

7 Drive Machine Data (SIMODRIVE Drive MD)

7.3.2 Drive MD (data description)

Note:

Reset 611D alarms can be acknowledged via a software reset.

Caution:

Concealing the reset alarms may result in irreparable damage to the power section.

Concealable alarms (Reset)

1601

Default value

Lower input limit

Upper input limit

Units

0000

0000

FFFF

Hex

Active

at once

This machine data allows reset 611D alarms to be concealed or disabled. The alarm is active if
the appropriate bit = 0. All 611D alarms are activated as standard.

Value table:

Bit 0

Configuration error - not concealable

Bits 1-5

Not assigned

Bits 6

Flux controller at stop

Bits 7

Current controller at stop

Bit 8

Speed controller at fixed stop

Bit 9

Encoder limit frequency exceeded

Bits 10-11

Not assigned

Bit 12

Speed too high for system power-up

Bit 13

Temperature motor shutdown (temperature)

Bit 14

Temperature motor shutdown (timer)

Bit 15

Not assigned

Note:

Reset 611D alarms can be acknowledged via a software reset.

Caution:

Concealing the reset alarms may result in irreparable damage to the power section or the
motor.

Motor temperature warning threshold

1602

Default value

Lower input limit

Upper input limit

Units

120

0

200

°C

Active

at once

Input of thermally constant permissible motor temperature or automatic parameterization using
machine data "Motor code number" (MD 1102). The temperature is detected by appropriate
temperature sensors and evaluated in the drive. A message is transferred to the SERVO when
the warning limit is exceeded (see also MD 1603 and MD 1607). Reset 611D alarms can be
switched to 611D warnings via MD 1012 bit 4 making the conceal function ineffective.

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

7–135

SINUMERIK 840C (IA)