06.93

12 Functional Descriptions

12.13.7 Actual value display

The division counter display is shown in the following example (example for display
resolution 10 E - 3 mm).

99999.123

CC

The places after the decimal point are used to check
travel and to display a non-division position

The number of displayed decimal places after the point depends on the set display resolution.
The division counter includes the division offset (MD 1112*) in its calculations. The division
offset shows which actual value corresponds to indexing position 1 (offset=0: actual value=0
corresponds to indexing position 1).

Actual value No.

Actual value identification

Actual value division related

0

DRF offset

––––––––

1

PRESET offset

X

2

––––––––

––––––––

3

Actual offset (TO+ZO)

––––––––

4

Actual position

X

5

Distance to go

––––––––

6

JOG offset

––––––––

7

Workpiece related actual value

X

8

Simulation actual value

––––––––

9

Interpolation actual value

––––––––

10

Machine-related actual value with
following error

––––––––

© Siemens AG 1992 All Rights Reserved 6FC5197- AA50